Availability: | |
---|---|
Quantity: | |
GT-MFI-450BC
GT-TEST
9024800000
Melt FLow Indexer for PE and PVC
Standards
ISO 1133
ASTM D 1238
ASTM D 3364
Application
It is a new and affordable tabletop instrument that tests the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of a wide range of thermoplastic raw materials, in the form of granules, strips of film etc, which is particularly useful for quality control tests on thermoplastics.
Features
l The instrument is with panel for a simple and fast input of the test parameters, visualization of test execution and final results. Also, test result can be print out via a built-in printer.
l Both Melt flow rate (MFR) and Melt volume rate (MVR) can be determined through a calibrated die under the effect of a pre-determined force, at constant temperature.
l Piston displacement monitored by encoder; storing and printing whenever necessary.
l It is supplied completely with all the accessories and weights necessary for maintenance and operation.
Technical Parameters
Temperature Control Range: 50°C to 450°C
Temperature Accuracy: +/- 0.1°C
Temperature Recovery time:< 4min
Accuracy of timer: 0.01°C
Displacement Accuracy: ± 0.02mm
Equipped with Die Plug function
Weights: 0.325, 1.2, 2.16, 3.8, 5.0, 10, 20 and 21.6kg
Measurement range: (1.0g -100g)/10 Min (MFR) / (0.01 -350cm3)/10min(MVR)
Electrical Requirement: 220V 50HZ/60HZ
Melt FLow Indexer for PE and PVC
Standards
ISO 1133
ASTM D 1238
ASTM D 3364
Application
It is a new and affordable tabletop instrument that tests the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of a wide range of thermoplastic raw materials, in the form of granules, strips of film etc, which is particularly useful for quality control tests on thermoplastics.
Features
l The instrument is with panel for a simple and fast input of the test parameters, visualization of test execution and final results. Also, test result can be print out via a built-in printer.
l Both Melt flow rate (MFR) and Melt volume rate (MVR) can be determined through a calibrated die under the effect of a pre-determined force, at constant temperature.
l Piston displacement monitored by encoder; storing and printing whenever necessary.
l It is supplied completely with all the accessories and weights necessary for maintenance and operation.
Technical Parameters
Temperature Control Range: 50°C to 450°C
Temperature Accuracy: +/- 0.1°C
Temperature Recovery time:< 4min
Accuracy of timer: 0.01°C
Displacement Accuracy: ± 0.02mm
Equipped with Die Plug function
Weights: 0.325, 1.2, 2.16, 3.8, 5.0, 10, 20 and 21.6kg
Measurement range: (1.0g -100g)/10 Min (MFR) / (0.01 -350cm3)/10min(MVR)
Electrical Requirement: 220V 50HZ/60HZ